Skip to content

Initial states and model parameters

Junction model domains

Model values must be finite. RTYPE is exactly 0 or 1; RN, R0, DELV, ICFCT, GWIDTH and TC are positive. C can be zero. D is in [0,1]. The ordinary sinusoidal model permits signed or zero Ic. The temperature-dependent CPR additionally requires positive Ic and 0<=T<TC. Effective junction area must be positive; an IC override requires a nonzero model Ic. C++ model objects receive the same validation as parsed netlists, including after area/temperature scaling.

At finite positive temperature, D=1 is supported, including the regularized current limit at phase pi. At zero temperature, the fully transparent CPR has a discontinuous cusp. A point numerically at that cusp is rejected; finite positive temperature or a resolved point on either side has a defined value. Arbitrary harmonic/transparency combinations must keep their square-root argument nonnegative throughout the run.

The temperature-dependent superconducting expression does not model operation at or above Tc. For a prescribed normal-state RC junction, use RTYPE=0 IC=0 with the chosen RN and C, without enabling that temperature-dependent CPR. Instance TEMP=/global .temp controls thermal noise separately; it does not create a temperature trajectory or automatically switch superconductivity at Tc.

An invalid model or non-finite solved state stops the simulation with an error.

Capacitor voltage (#109)

Set IC= on a capacitor to specify its voltage at physical time zero, in volts. The sign is V(positive terminal)-V(negative terminal). Use DST on .TRAN to disable automatic settling, which would otherwise change the requested state:

R1 N 0 10
C1 N 0 1p IC=1m
.tran 0.1p 100p DST
.print V(C1) I(C1) I(R1)
.end

The first sample has V(C1)=1 mV and I(C1)=-100 uA. With tau=RC=10 ps, the ideal discharge is V(t)=1m*exp(-t/10p). The complete example is included in the source tree.

IC= accepts finite signed values and scoped parameter expressions, including subcircuit instance parameters. Capacitance must be finite and positive. The initializer solves the coupled node voltages, branch currents and voltage derivatives, then constructs consistent integration histories in both analysis modes. A timestep restart reapplies the same initial conditions. A later print start omits samples from the output, without moving the physical initial time.

Unspecified independent capacitor voltages start at zero. Constraints already imposed by other capacitors or ideal voltage sources take precedence, so parallel capacitors share their voltage and derivative. Conflicting capacitor loops or source voltages are errors. Inductor currents and junction phases start at zero; transmission lines start without incoming waves. The circuit still needs enough connections to determine its node voltages; IC does not supply a ground reference.

This initial-voltage path currently rejects circuits containing phase sources or controlled sources. It does not provide a DC operating-point solve or general SPICE .IC/UIC semantics. UIC retains its existing behavior; DST is required. The request is tracked in #109.

Without explicit capacitor IC, startup keeps its existing zero-history behavior. Default startup advances that state for a finite negative-time settling interval; DST disables the interval.

If other circuit states need physical preparation, include the charging circuit and a long enough interval before the event of interest. For example:

V1 IN 0 PWL(0 1m 200p 1m 202p 0 300p 0)
R1 IN OUT 10
C1 OUT 0 1p
.tran 0.1p 300p DST
.print V(IN) V(C1) I(R1) I(C1) I(V1)
.end

Here tau=RC=10 ps. The capacitor charges for 20 tau, then discharges through the resistor after the source falls. The source's finite fall time is part of the physical preparation. This does not instantly assign voltage at t=0 or remove the charging circuit. Use the actual preparation network when it affects other circuit states. A later print-start value can omit preparation from the output while retaining it in the simulation.

A complete charging example is included in the source tree.

Stewart–McCumber parameter (#93)

For a sinusoidal RCSJ junction with constant shunt resistance R,

\[ \beta_c=\frac{I_c C R^2}{\sigma},\qquad R=\sqrt{\frac{\beta_c\sigma}{I_c C}},\qquad \sigma=\frac{h}{4\pi e}. \]

R is in ohms, Ic in amperes and C in farads. For RTYPE=0, set BETA_C directly; JoSIM calculates RN once after parsing the model:

.param BETA=1 ICVAL=1u CVAL=0.1p
.model JM JJ(RTYPE=0 IC=ICVAL CAP=CVAL BETA_C=BETA)

This gives R approximately 57.36776 ohms for beta_c=1, using JoSIM's Josephson constant SIGMA=3.291059757e-16 V*s. BETA_C accepts parameter expressions in the model's scope. Model defaults for Ic and C apply when omitted; all three values must be finite and positive, and the calculated RN must be finite and nonzero. For zero or negative Ic, or C=0, specify RN instead.

Specify RTYPE=0 explicitly: the default is 1. An explicit RN alongside BETA_C, duplicate BETA_C assignments, and temperature-dependent model parameters T, TC or D are errors. The temperature-dependent model derives its own RN, so it cannot also use this conversion. Instance TEMP= and global .TEMP control thermal noise separately and are compatible with BETA_C.

Normal AREA and instance IC scaling still apply: Ic and C scale with area, while RN scales inversely. Their product Ic*C*RN^2, and hence nominal beta_c, is preserved. RTYPE=0 uses RN throughout, including in place of R0.

The complete example is checked against explicit RN and the physical current relation I=Ic*sin(phi)+V/R+C*dV/dt for beta_c=0.2, 1 and 5 in both modes, including AREA and instance IC overrides. To calculate RN in a parameter expression, use SQRT(BETA*3.291059757e-16/(ICVAL*CVAL)).

RTYPE=1 has different subgap, transition and normal-state conductance. It has no single global damping resistance: a beta_c quoted with R0 describes a different operating assumption from one quoted with RN. Gate control, critical-current noise, temperature and a non-sinusoidal CPR can also change the effective damping/stiffness. BETA_C therefore describes nominal damping based on the model Ic scale. Direct input for RTYPE=1 remains unsupported; choose its resistances explicitly. The request is tracked in #93.

Current-dependent inductance (#88)

Add ALPHA= to an L component for a quadratic kinetic-inductance approximation:

.param KINETIC=1e8
L1 IN OUT 100p ALPHA=KINETIC

VALUE is the zero-current inductance L0 in H. ALPHA is a in A^-2. JoSIM uses differential inductance, with the self-flux law

\[ L_d(I)=\frac{d\Phi_s}{dI}=L_0(1+aI^2),\qquad \Phi_s(I)=L_0\left(I+\frac{aI^3}{3}\right),\qquad V=\frac{d\Phi_s}{dt}. \]

For the example, Ld is 200 pH at 100 uA, while Phi_s/I is about 133.3 pH. The distinction matters: interpreting L0*(1+a*I^2) as Phi/I would give a different flux law and three times the nonlinear contribution to Ld.

L0 must be finite and positive; a must be finite and non-negative. Both accept scoped parameter expressions, resolved once before the run. SPREAD= scales L0 through the existing inductor spread rules. The polynomial is evaluated numerically during solving; ALPHA=0 or omission retains constant L. This is a prescribed constitutive law, not a general runtime expression or microscopic material model. Flux, differential inductance and matrix coefficients must stay within the numerical range.

For coupled inductors, the total linkage is

\[ \Phi_i=\Phi_{s,i}(I_i)+\sum_{j\ne i}M_{ij}I_j,\qquad M_{ij}=M_{ji}=k_{ij}\sqrt{L_{0i}L_{0j}}. \]

M is constant and uses the zero-current inductances. A connected coupling group containing a nonlinear inductor must have a positive-definite base inductance matrix at numerical precision. Pairwise |k|<1 alone does not establish this for three or more coils. Perfect coupling, nearly singular groups and self-coupling are rejected. With a>=0, the additional diagonal differential inductance preserves positivity as current changes.

The stored energy of one uncoupled element is

\[ W(I)=L_0\left(\frac{I^2}{2}+\frac{aI^4}{4}\right). \]

For a coupled group, sum those energies and add Mij*Ii*Ij once per pair. Initial currents follow the existing startup or capacitor-initial-voltage procedure. No inductor IC= option is provided. A nonlinear LC example starts with capacitor energy and zero inductor current.

Voltage mode applies BDF2 to total flux linkage. Phase mode solves the corresponding flux/phase constraint. Both use bounded Newton correction for the nonlinear inductor equations; see numerical methods. The request is tracked in #88.